Cable Planner

Power and DMX cabling straight from the Lighting & Rigging Planner: circuits with overcurrent protection, RCDs and phases to DIN VDE, voltage drop and disconnection check per chain, DMX lines with unit loads, addresses and terminator, plus cable routes, schematic and cable list. Every change in the lighting plot is recalculated instantly.

Connecting to the Lighting & Rigging Planner …To the lighting plot
    Mouse wheel zooms, dragging pans. Distros, racks and the DMX node can be moved. Clicking a device shows its circuit and line.
    Circuits
    CircuitDistroPhaseMCBRCDFixturesPScos φIbUtilisationHome runΔUZs / Zs,maxCheck
    RCDDistroCirclesLeakage currentLimit
    DistroL1L2L3ImbalanceOutputs
    DMX lines
    LineUniverseSourceFixtures and addressesUnit loadsChannelsLengthTerminator
    Cable list
    CableLengthQuantityTotal
    Adapters and accessoriesQuantity
    No.CableoftoLength
    Distros, supply and DMX node
    Distro / locationSupplyOutputsOvercurrent protectionRCDCircuits per RCDOutletPosition
    Power distros placed as objects in the lighting plot are picked up automatically and stay linked to their position.
    Cables and limits

    Enter Iz to DIN VDE 0298-4 (flexible cables) for your installation method. Without an entry the planner uses the conservative placeholder values. The grouping factor applies as soon as more than three loaded circuits run together along a truss; then κ = 48 instead of 56 m/(Ω·mm²) is used too.

    Fixture data

    Enter values from the data sheet. Empty fields use the default (grey) and are listed as assumptions in the notes. Power comes from the lighting plot or the GDTF file.

    DeviceQtyPTypecos φLeakage current (mA)Power inPower outMax. link-through (A)DMX in / outData viaUnit load

    How it works

    The cable planner reads trusses, fixtures, power distros and the FOH position live from the Lighting & Rigging Planner, even when the lighting plot is open in a second window. On each truss it orders the fixtures along the truss, starts at the end closest to the distro and daisy-chains without doubling back. A chain is split as soon as a limit is reached: operating current with planning reserve, cable current rating including grouping, the fixtures' link-through current, leakage current behind the RCD (at most 30 % of IΔn), voltage drop (4 % minus upstream drop) and the disconnection condition of the circuit breaker at the farthest fixture. If a chain still has headroom at the truss end and another truss starts there, it continues instead of a new home run. Circuits are then balanced across L1, L2 and L3 per distro.

    DMX lines follow the same order as the power chains, at most 32 unit loads, one universe per line, ending in a 120 Ω terminator. Addresses are taken from the patch list; on request the planner assigns them without gaps in chain order and writes them back to the lighting plot.

    Calculations use apparent power S = P / cos φ, 100 % diversity and the arithmetic sum of currents. Cable lengths are the route plus 0.5 m between fixtures, or floor route plus trim height plus 2 m for home runs, rounded up to the lengths in your stock. Voltage drop uses the cable length actually used.

    About Stagetab

    All calculations run locally in your browser. Nothing you enter is transmitted; run sheets and soundboard labels are stored on your device only.

    The calculators provide guide values for planning and setup. Manufacturer data, on-site measurements and safety regulations always take precedence.

    Need technical production for your event?

    ES-Sound plans and runs sound, lighting and video for corporate events, concerts and celebrations.

    Request a quote

    Licences & trademarks

    Terms of use

    1. Stagetab may be used free of charge for planning and running your own events, including commercially.
    2. Redistribution, sale, modification, reverse engineering and copying parts of the software into other products are not permitted. Stagetab is provided exclusively via es-sound.de.
    3. All calculations (e.g. loads, power, levels) are guide values and do not replace checks by competent personnel. The user or the responsible specialist on site is responsible for set-up, safety and sign-off.
    4. Stagetab is provided without warranty. ES-Sound is only liable for intent and gross negligence, as far as permitted by law.
    5. Project data stays in your browser or on your computer. Stagetab does not send any project data to ES-Sound.

    Software, data and fonts

    The ES-Sound Stagetab uses the following software, data and fonts. The full licence texts are included with the files.

    ComponentRights holderLicence
    three.js (3D rendering)three.js authorsMIT
    systray (hardware bridge tray icon)Fyne.io project, GetlanternApache 2.0
    godbus (hardware bridge on Linux)Georg Reinke and contributorsBSD 2-Clause
    Go x/sys (hardware bridge on Windows)The Go AuthorsBSD 3-Clause
    MapLibre GL JS (map in the site plan)MapLibre contributorsBSD 3-Clause
    Map data in the site plan (only when a map is selected)OpenFreeMap, OpenMapTiles, OpenStreetMap contributorsODbL
    PDF.js (PDF as floor plan)Mozilla FoundationApache 2.0
    ONNX Runtime WebMicrosoft CorporationMIT
    AI model “Beat This!” (beat tracking)Institute of Computational Perception, JKU Linz; Johannes GorsetMIT
    Essentia models for mood detection (AI module only)Music Technology Group, Universitat Pompeu Fabra, BarcelonaCC BY-NC-SA 4.0
    fft.jsFedor IndutnyMIT
    Open Fixture Library (fixture data)Florian & Felix Edelmann and contributorsMIT
    GDTF files from GDTF Share (Powered by GDTF)Manufacturers or users who uploaded the file; GDTF Share by MA Lighting, Robe and VectorworksTerms of use of gdtf-share.com; GDTF is DIN SPEC 15800
    Fonts Barlow Condensed, IBM Plex Sans, JetBrains MonoJeremy Tribby; IBM Corp.; JetBrains s.r.o.SIL Open Font License 1.1
    Windows app: Electron and ChromiumOpenJS Foundation, The Chromium AuthorsMIT and others, see program folder

    GDTF and MVR are open formats according to DIN SPEC 15800. The lighting plot symbols follow the USITT recommendations (RP-2) and are our own drawings.

    Trademarks

    Product and company names mentioned, e.g. of fixture, truss and console manufacturers, are trademarks of their respective owners. They are used only to identify devices, formats and compatibility. The Stagetab is not affiliated with or endorsed by these manufacturers. Manufacturers' fixture files remain their property.

    The cable planner turns your lighting plot into complete power and DMX cabling. It reads trusses, fixtures and power distros live from the Lighting & Rigging Planner. Then it builds power chains and DMX lines, checks them and writes a cable list. The tool is free and runs in your browser without sign-up.

    Cable planner showing cable routes, power chains and DMX lines over a lighting plot

    What the cable planner is for

    On many jobs the cabling only takes shape during load-in. Then a long cable is missing, or a chain carries too much. With a plan in advance, you already know in the warehouse which lengths to pack. You also see beforehand which circuits sit on which phase.

    • Power circuits per truss with overcurrent protection, RCD and phase
    • Voltage drop and disconnection check for every chain
    • DMX lines with unit loads, addresses and terminator
    • Cable routes in plan view and a schematic in the style of ConnectCAD
    • Cable list with your stock lengths, plus export as PDF, CSV or JSON

    Checking circuits to DIN VDE

    For every chain the tool checks several limits. These include operating current with reserve, the cable rating to DIN VDE 0298-4 and the fixtures' link-through current. It also watches leakage current behind the RCD and voltage drop. The basis is parts 410, 430, 520, 530 and 711 of DIN VDE 0100.

    Once a chain hits a limit, the planner splits it. After that, it balances the circuits across L1, L2 and L3 for each distro. For a quick overview of the standard series, see Baunetz Wissen on DIN VDE 0100 (in German).

    Important: the cable planner is a planning aid. Installation, testing and measurement remain the job of a qualified electrician. Therefore the plan never replaces verification on site.

    DMX lines in the cable planner

    DMX lines follow the same order as the power chains. As a result, the data cable usually runs alongside the power. Each line carries at most 32 unit loads and one universe. A 120 Ω terminator always sits at the end. If you like, the cable planner assigns addresses without gaps and writes them back to the lighting plot. Background on the protocol is on Wikipedia: DMX512.

    Tips from the field

    First, enter the cable lengths from your stock. Then the tool rounds every run up to a cable you actually own. Also check the trim height of the trusses, because it feeds into the length of the home runs. If you change something in the lighting plot later, the cabling updates instantly.

    For quick load balancing without a lighting plot, use the power and phase balancing tool. You will find more free calculators for lighting, sound and video in the Stagetab.